Kleenmaid CH311XFF User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
8
INSTALLATION INSTRUCTIONS
INSTRUCTIONS FOR INSTALLATION
This appliance must be installed only by authorised personnel and in accordance with manufacture’s
installation instructions, local gas fitting regulations, municipal building codes, water supply regulations,
electrical wiring regulations AS 5601/AG601- Gas Installations and any other statutory regulations.
§ Gas safety regulations (Installation & Use)
§ Kleenmaid Installation Instructions.
POSITIONING THE APPLIANCE
Combustible Surfaces – Any adjoining wall surface situated within 200mm from the edge of any
cooktop burner must be a suitable non-combustible material for a height of 150mm for the entire length
of the cooktop. Any combustible construction above the hotplate must be at least 600mm above the
top surface of the bench and no construction shall be within 450mm above the top of the burner. Allow
a 10mm minimum clearance below the hotplate.
Ventilation – Ventilation must be in accordance with AS5601/AG601 installations. In general, the
appliance should have adequate ventilation for complete combustion of gas, proper flueing and to
maintain temperature of immediate surroundings within safe limits.
PRE-COMMISSIONING THE APPLIANCE
When unpacked, check that the following parts are included with the appliance: -
§ Kleenmaid Instruction and Installation Book
§ Pan Supports
§ Burner Assemblies
§ Adhesive sealing strip and fixing clamps & screws
§ ½ BSP Elbow & Seal
§ LPG conversion kit comprising of a LPG jet for each burner and a self-adhesive label for amending
Gas Category on the appliance Rating Label.
The appliance is factory set for Natural gas. The test point pressure should be adjusted to 1.00 kPa
with the relevant burners operating at maximum as in the table below.
MODEL T.P.P. (kPa) Burners
CH311XFF 1 Rapid
CH311WOKFF 1 Wok
CH607X CH607W 1 Rapid + Semi Rapid
CH609X CH609W 1 Wok + Semi Rapid
CH611XFF CH611WFF 1 Wok + Rapid
CH711XFF 1 Wok + Rapid
CH911XFF 1 Rapid + Semi Rapid
CH915XFF CH915AFF 1 Rapid + Semi Rapid
CH920XFF 1 Wok + Rapid
Page view 8